Description
Ultrasonic Sensors | Liquids | General Purpose & Intrinsically Safe
EchoPod® DL10 Ultrasonic Liquid Level Transmitter
EchoPod® DL10 Ultrasonic Liquid Level Transmitter
APPLICATION
The general purpose ultrasonic level transmitter provides continuous level measurement up to 49.2” (1.25m) with a 4-20 mA signal output, and is configured via our free WebCal software. This non-contact liquid level sensor is ideally suited for corrosive, sticky or waste liquids, and is selected for chemical feed, IBC or drum, skid or machine and cooling tower applications.
FEATURES
- Continuous non-contact level measurement up to 49.2” (1.25m)
- 4-20 mA output for longer signal distances up to 1000’ (300m)
- Configuration is fast and easy via WebCal software and USB adapter
- Narrow 2” beam width and short 2” dead band optimized for small tanks
- PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
- Automatic temperature compensation for accurate measurement
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 49.2” (1.25m)
Accuracy: 0.125” (3mm)
Resolution: 0.019” (0.5mm)
Dead band: 2” (5cm)
Beam width: 2” (5cm)
Configuration: WebCal™ PC, Windows®, USB 2.0
Memory: Non-volatile
Supply voltage: 24 VDC (loop)
Consumption: 0.5W
Loop resist.: 400Ω max
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4mA
Loop fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Process temp.: F: 20° to 140°, C: -7° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -31° to 140°, C: -35° to 60°
Pressure: MWP = 30 PSI (2 bar)
Enclosure rating: Type 6P, encapsulated, corrosion resistant & submersible
Encl. material: Polycarbonate
Strain relief mat.: Santoprene
Trans. material: PVDF
Cable jacket mat.: Polyurethane
Cable type: 4-conductor, shielded
Cable length: 48” (1.2m)
Process mount: 1” NPT (1” G)
Mount gasket: Viton®
Classification: General purpose
Compliance: CE, RoHS
Approvals: cFMus
EchoPod® DL14 Multi-Function Ultrasonic Liquid Level Transmitter
EchoPod® DL14 Multi-Function Ultrasonic Liquid Level Transmitter
APPLICATION
The general purpose ultrasonic transmitter provides continuous level measurement up to 49.2” (1.25m) with a 4-20 mA signal output and four relays, and is configured via our free WebCal software. Each relay is fully configurable for automatic fill, empty or alarm functions, and the embedded level controller may lower cost by replacing external control hardware. This non-contact liquid level sensor is well suited for corrosive, sticky or waste liquids, and is selected for IBC or drum, skid or machine and cooling tower applications.
FEATURES
- Level measurement, switch and control functions up to 49.2” (1.25m)
- Configuration is fast and easy via WebCal software and USB adapter
- Narrow 2” beam width and short 2” dead band optimized for small tanks
- Four programmable relays for switch, pump or valve control and fail-safety
- 1 pump or valve with 3 alarms
- 2 pumps lead-lag with 2 alarms
- 2 pumps duplexing with 2 alarms
- 4 independent switch point alarms
- PVDF transducer and 6P polycarbonate enclosure for corrosive liquids
- Automatic temperature compensation for accurate measurement
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 49.2” (1.25m)
Accuracy: 0.125” (3mm)
Resolution: 0.019” (0.5mm)
Dead band: 2” (5cm)
Beam width: 2” (5cm)
Configuration: WebCal™ PC, Windows®, USB 2.0
Memory: Non-volatile
Supply voltage: 24 VDC (loop)
Consumption: 0.5W
Loop resist.: 400Ω max
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA or 20-4mA
Signal fail-safe: 4 mA, 20 mA, 21 mA, 22 mA or hold last
Contact type: (4) SPST relays, 1A
Contact fail-safe: Power loss: Hold last, Power on: Open, close or hold last
Hysteresis: Selectable
Process temp.: F: 20° to 140°, C: -7° to 60°
Temp. comp.: Automatic
Ambient temp.: F: -31° to 140°, C: -35° to 60°
Pressure: MWP = 30 PSI (2 bar)
Enclosure rating: Type 6P, encapsulated, corrosion resistant & submersible
Encl. material: Polycarbonate
Strain relief mat.: Santoprene
Trans. material: PVDF
Cable jacket mat.: Polyurethane
Cable type: 9-conductor, shielded
Cable length: 48” (1.2m)
Process mount: 1” NPT (1” G)
Mount gasket: Viton®
Classification: General purpose
Compliance: CE, RoHS
Approvals: cFMus
EchoPod® UG01 & UG03 Reflective Ultrasonic Multi-Function Liquid Level Transmitter
EchoPod® UG01 & UG03 Reflective Ultrasonic Multi-Function Liquid Level Transmitter
APPLICATION
The general purpose reflective ultrasonic multi-function level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
FEATURES
- Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
- Fail-safe diagnostics with selectable relay and signal outputs
- Narrow 2” (5cm) beam width for applications with limited space
- Corrosion resistant PVDF transducer and compact PP enclosure
- Short 1.5” (3.8cm) dead band maximizes tank filling capacity
- Automatic temperature compensation from -40º to 80º C.
- Four programmable relays with embedded level control logic
- 1 pump or valve with 3 alarms
- 2 pumps lead-lag with 2 alarms
- 2 pumps duplexing with 2 alarms
- 4 independent switch point alarms
REFLECTIVE
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer
Reliable Measurement
Horizontal Transducer
Signal Attenuation
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: UG01: 1.5” to 4.9’ (3.8cm to 1.5m), UG03: 4” to 9.8’ (10.1cm to 3m)
Accuracy: UG01: 0.125” (3mm), UG03: ± 0.2% of range
Resolution: UG01: 0.019” (0.5mm), UG03: 0.039” (1mm)
Dead band: UG01: 1.5” (3.8cm), UG03: 4” (10.1cm)
Beam width: 2” (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply voltage: 14-28 VDC
Max. consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Contact type: (4) SPST relays
Contact rating: 60 VA, 1A maximum
Contact fail-safe: Open, closed, hold last
Contact hysteresis: Selectable
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º, C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Cable jacket mat.: Polyurethane
Cable type: 9-conductor, shielded
Cable length: 48” (1.2m)
Process mount: -0001: 2” NPT, -0011: 2” G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approval (pending): UL 61010-1
Compliance: CE, RoHS
EchoPod® UG06 & UG12 Reflective Ultrasonic Liquid Level Transmitter
EchoPod® UG06 & UG12 Reflective Ultrasonic Liquid Level Transmitter
APPLICATION
The general purpose reflective ultrasonic level transmitter provides continuous level measurement up to 39.3’ (12m) with a 4-20 mA analog signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.
FEATURES
- Offered in 6m (19.6’) and 12m (39.3’) measurement ranges
- Reflective Technology™ measures reliably with condensation
- Corrosion resistant PVDF transducer with IP68 PP enclosure
- Fail-safe diagnostics with selectable signal fail-safe outputs
- LCD display indicates level in inches, meters or percent of span
- Narrow 3” (7.6cm) beam width for applications with limited space
- Windowed enclosure cap provides liquid tight level indication
- Configuration via push button display or WebCal software
- Automatic temperature compensation from -40º to 80º C.
REFLECTIVE
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer
Reliable Measurement
Horizontal Transducer
Signal Attenuation
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
SPECIFICATIONS
Range: UG06: 8” to 19.6’ (20cm to 6m), UG12: 18” to 39.3’ (45.7cm to 12m)
Accuracy: ± 0.2% of range
Resolution: UG06: 0.079” (2mm), UG12: 0.196” (5mm)
Dead band: UG06: 8” (20.3cm), UG12: 18” (45.7cm)
Beam width: UG06: 3” (7.6cm), UG12: 6” (15.2cm)
Configuration: Push button or WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm or percent
Supply voltage: 14-28 VDC
Max. consumption: 0.5W
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º, C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Encl. cap material: Clear polycarbonate
Enclosure vent: Water tight membrane
Conduit entrance: 1/2” NPT
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Process mount: -0001: 2” NPT, -0011: 2” G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: General purpose
Approval (pending): UL 61010-1
Compliance: CE, RoHS
EchoTouch® US01 & US03 Reflective Ultrasonic Liquid Level Transmitter
EchoTouch® US01 & US03 Reflective Ultrasonic Liquid Level Transmitter
APPLICATION
The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for small tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
FEATURES
- Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
- Reflective Technology™ measures reliably with condensation
- Narrow 2” (5cm) beam width for applications with limited space
- Configuration is easy with WebCal software and USB adapter
- Short 1.5” (3.8cm) dead band maximizes tank filling capacity
- PVDF transducer and PP enclosure for corrosive environments
- Fail-safe diagnostics with selectable fail-safe signal outputs
- Type 6P (IP68) compact enclosure for small tank applications
- Automatic temperature compensation from -40º to 80º C.
REFLECTIVE
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer
Reliable Measurement
Horizontal Transducer
Signal Attenuation
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: US01: 1.5” to 4.9’ (3.8cm to 1.5m), US03: 4” to 9.8’ (10.1cm to 3m)
Accuracy: US01: 0.125” (3mm), US03: ± 0.2% of range
Resolution: US01: 0.019” (0.5mm), US03: 0.039” (1mm)
Dead band: US01: 1.5” (3.8cm), US03: 4” (10.1cm)
Beam width: 2” (5cm)
Configuration: WebCal® PC Windows® USB® 2.0
Memory: Non-volatile
Supply voltage: 14-28 VDC
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -31º to 140º, C: -35º to 60º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Polypropylene
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Cable jacket mat.: Polyurethane
Cable type: 4-conductor, shielded
Cable length: 48” (1.2m)
Process mount: -0001: 2” NPT, -0011: 2” G
Mount gasket: -0001: N/a, -0011: Viton®
Classification: Intrinsically safe
Approvals (pending): Haz Loc: Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class III; Class I, Zone 0, Group IIC, Zone 20, Group IIC; IECEx: II 1G, EEx ia IIC Gc
Entity parameters: See control drawing #610125
Compliance: CE, RoHS
EchoTouch® US06 & US12 Reflective Ultrasonic Liquid Level Transmitter
EchoTouch® US06 & US12 Reflective Ultrasonic Liquid Level Transmitter
APPLICATION
The intrinsically safe reflective ultrasonic level transmitter provides continuous level measurement up to 39.3’ (12m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Select this sensor for bulk tanks with non-foaming or highly vaporous media such as chemicals, water, wastewater and oil. Typical applications include bulk storage, neutralization tank, clarifier and waste sumps.
FEATURES
- Offered in 6m (19.6’) and 12m (39.3’) measurement ranges
- Reflective Technology™ measures reliably with condensation
- Corrosion resistant PVDF transducer with aluminum enclosure
- Narrow 3” (7.6cm) beam width for applications with limited space
- LCD display indicates level in inches, meters or percent of span
- HART communication in point to point and multi-drop modes
- Fail-safe diagnostics with selectable fail-safe signal outputs
- Configuration via push button display or WebCal software
- Automatic temperature compensation from -40º to 80º C.
REFLECTIVE
Condensation is the most common variable in liquid level applications. Condensation attenuates the acoustic signal of ultrasonic sensors with horizontal transducers, weakening their signal strength and signal to noise ratio by up to 50%, and substantially reducing their measurement reliability. At the core of Reflective Technology™ is a simple fact. Unlike flat horizontal surfaces, significant water droplets cannot adhere to smooth vertical surfaces. By orienting the transducer vertically, condensation runs off the transducer and does not affect sensor performance. The unimpeded transmit and receive signals are redirected to and from the liquid off a 45º reflector, delivering reliable level measurement. Thanks gravity.
Reflective Transducer
Reliable Measurement
Horizontal Transducer
Signal Attenuation
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: US06: 8” to 19.6’ (20cm to 6m), US12: 18” to 39.3’ (45.7cm to 12m)
Accuracy: ± 0.2% of range
Resolution: US06: 0.079” (2mm), US12: 0.196” (5mm)
Dead band: US06: 8” (20.3cm), US12: 18” (45.7cm)
Beam width: US06: 3” (7.6cm), US12: 6” (15.2cm)
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7 (pending)
Memory: Non-volatile
Display type: LCD, 6-digit
Display units: Inch, cm or percent
Supply voltage: 14-28 VDC
Loop resistance: 500 ohms @ 24 VDC
Signal output: 4-20mA, two-wire, HART 7 (pending)
Signal invert: 4-20mA or 20-4mA
Signal fail-safe: 4mA, 20mA, 21mA, 22mA, hold last
Process temp.: F: -40º to 176º, C: -40º to 80º
Temp. comp.: Automatic
Ambient temp.: F: -40º to 176º, C: -40º to 80º
Pressure: 30 psi (2 bar)
Enclosure rating: Type 6P (IP68)
Encl. material: Aluminum
Enclosure vent: Water tight membrane
Conduit entrance: 1/2” NPT
Transducer type: Reflective
Transducer mat.: Polyvinylidene fluoride
Process mount: -0003: 2” NPT, -0013: 2” G
Mount gasket: -0003: N/a, -0013: Viton®
Classification: Intrinsically safe
Approvals (pending): Haz Loc: Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class III; Class I, Zone 0, Group IIC, Zone 20, Group IIC; IECEx: II 1G, EEx ia IIC Gc
Entity parameters: See control drawing #600820
Compliance: CE, RoHS