Description
Pulse Radar Sensors | Liquids | Intrinsically Safe
Series | LR11 | LR16 | LR21 | LR26 | LR31 |
Classification | Intrinsically safe | Intrinsically safe | Intrinsically safe | Intrinsically safe | Intrinsically safe |
Media | Liquids | Liquids | Liquids | Liquids | Liquids |
Application | Storage | Storage | Storage | Process | Lift station |
Process condition | Easy | Difficult | Difficult | Extreme | Difficult |
Tank location and material | Above grade metal or below grade in any tank material | Above or below grade in any tank material | Above or below grade in any tank material | Above grade metal or below grade in any tank material | Below grade in any tank material |
Corrosive | Yes | Diluted | Yes | Yes | Diluted |
Range | 32.8′ (10m) | 98.4′ (30m) | 65.6′ (20m) | 114.8′ (35m) | 98.4′ (30m) |
Output | 4-20 mA + HART® | 4-20 mA + HART® | 4-20 mA + HART® | 4-20 mA + HART® | 4-20 mA + HART® |
Installation | Tank adapter or flange | Tank adapter or flange | Flange | Flange | Bracket |
Mount | 1 1/2″ NPT | 1 1/2″ NPT | 3″, 4″ ANSI | 4″, 6″ ANSI | Bolt |
Max. temperature | 176º F. (80º C.) | 302º F. (150º C.) | 302º F. (150º C.) | 266º F. (130º C.) | 212º F. (100º C.) |
Max. pressure | 43.5 PSI (3 bar) | 150 PSI (10 bar) | 72 PSI (5 bar) | 580 PSI (40 bar) | Atmospheric |
Ant. material | PTFE | 316L | 316L & PTFE | 316L & PTFE | Nylon |
Pulse Radar Sensors | Liquids | General Purpose
Series | LR10 | LR15 | LR20 | LR25 | LR30 |
Classification | General purpose | General purpose | General purpose | General purpose | General purpose |
Media | Liquids | Liquids | Liquids | Liquids | Liquids |
Application | Storage | Storage | Storage | Process | Lift station |
Process condition | Easy | Difficult | Difficult | Extreme | Difficult |
Tank location and material | Above grade metal or below grade in any tank material | Above or below grade in any tank material | Above or below grade in any tank material | Above grade metal or below grade in any tank material | Below grade in any tank material |
Corrosive | Yes | Diluted | Yes | Yes | Diluted |
Range | 32.8′ (10m) | 98.4′ (30m) | 65.6′ (20m) | 114.8′ (35m) | 98.4′ (30m) |
Output | 4-20 mA | 4-20 mA | 4-20 mA | 4-20 mA | 4-20 mA |
Installation | Tank adapter or flange | Tank adapter or flange | Flange | Flange | Bracket |
Mount | 1 1/2″ NPT | 1 1/2″ NPT | 3″, 4″ ANSI | 4″, 6″ ANSI | Bolt |
Max. temperature | 176º F. (80º C.) | 302º F. (150º C.) | 302º F. (150º C.) | 266º F. (130º C.) | 212º F. (100º C.) |
Max. pressure | 43.5 PSI (3 bar) | 150 PSI (10 bar) | 72 PSI (5 bar) | 580 PSI (40 bar) | Atmospheric |
Ant. material | PTFE | 316L | 316L & PTFE | 316L & PTFE | Nylon |
Pulse Radar Sensors | Solids | Intrinsically Safe
Series | LR36 | LR41 | LR46 |
Classification | Intrinsically safe | Intrinsically safe | Intrinsically safe |
Media | Solids | Solids | Solids |
Application | Crusher, transfer station, bin | Crusher, transfer station, stockpile, silo, bin | Silo |
Process dust | Minimal | Moderate | Significant |
Range | 49.2′ (15m) | 229.7′ (70m) | 229.7′ (70m) |
Output | 4-20 mA + HART® | 4-20 mA + HART® | 4-20 mA + HART® |
Installation | Bracket or flange | Bracket or gimbal flange | Gimbal flange |
Mount | 1 1/2″ NPT, 4″ or 5″ ANSI | 1 1/2″ NPT, 4″ or 5″ ANSI | 4″ or 5″ ANSI |
Max. temperature | 392º F. (200º C.) | 752º F. (400º C.) | 752º F. (400º C.) |
Antenna type | Horn | Horn | Parabola |
Ant. air purge | No | Yes | No |
Ant. dust shield | No | Option | No |
Ant. material | 316L | 316L (with optional PTFE dust shield) | 316L |
EchoPro® LR11 Pulse Radar Liquid Level Transmitter
EchoPro® LR11 Pulse Radar Liquid Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy application conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.
FEATURES
- PFA encapsulated antenna and mount for corrosive media
- Configuration via push button display or WebCal software
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- HART communication in point to point and multi-drop modes
- Auto-temperature compensation for accurate measurement
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 32.8’ (30cm to 10m)
Frequency: 26 GHz.
Accuracy: ± 5mm
Dead band: 12” (30cm)
Beam angle: 22º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 266º, C: -40º to 130º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 43.5 psi (-1 to 3 bar)
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket and PBT FR neck
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: PFA
Process mount: 1-1/2” NPT
Classification: Intrinsically safe
Approvals (pending): ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, RoHS
EchoPro® LR16 Pulse Radar Liquid Level Transmitter
EchoPro® LR16 Pulse Radar Liquid Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor is intended for petroleum, water, wastewater and diluted chemical storage or process conditions in above or below grade tanks of any material. Select this sensor for challenging process conditions with low or non-corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a tank adapter, flange fitting or metal stand-pipe. Typical applications include bulk storage, tanker truck, RO storage, process tank, waste sump and neutralization tanks.
FEATURES
- Rugged 316L stainless steel antenna and process mount
- Configuration via push button display or WebCal software
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- HART communication in point to point and multi-drop modes
- Auto-temperature compensation for accurate measurement
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 98.4’ (30cm to 30m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 20: 18º, – 30: 12º, – 40: 8º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 302º, C: -40º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 150 psi (-1 to 10 bar)
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L
Process mount: 1-1/2” NPT
Classification: Intrinsically safe
Approvals (pending): ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, CRN, RoHS
EchoPro® LR21 Pulse Radar Liquid Level Transmitter
EchoPro® LR21 Pulse Radar Liquid Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.
FEATURES
- 316L antenna with PTFE inner shield for corrosive media
- Configuration via push button display or WebCal software
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- HART communication in point to point and multi-drop modes
- Auto-temperature compensation for accurate measurement
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 65.6’ (30cm to 20m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 30: 12º, – 40: 8º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 302º, C: -40º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 72 psi (-1 to 5 bar)
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L w/PTFE inner shield
Process mount: – 30: 3” flange (ANSI), – 40: 4” flange (ANSI)
Classification: Intrinsically safe
Approvals (pending): ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, CRN, RoHS
EchoPro® LR26 Pulse Radar Liquid Level Transmitter
EchoPro® LR26 Pulse Radar Liquid Level Transmitter
APPLICATION
The intrinsically safe 6.3 GHz. pulse radar transmitter provides continuous level measurement up to 114.8’ (35m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical and petroleum storage or process applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for harsh process conditions with corrosive or low dielectric media, heavy surface foam or agitation, higher pressure, steam, condensation or vapor, and installation in a flange fitting. Due to the wider beam angle, special attention should be given to ensure that the sensor is located with unobstructed measurement space. Typical applications include process tanks.
FEATURES
- 316L antenna with PTFE inner shield for corrosive media
- Simple configuration via integral push button display module
- 6.3 GHz. pulse radar is unaffected by most foam and agitation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- HART communication in point to point and multi-drop modes
- Auto-temperature compensation for accurate measurement
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 114.8’ (30cm to 35m)
Frequency: 6.3 GHz.
Accuracy: ± 10mm
Dead band: 12” (30cm)
Beam angle: 20º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 266º, C: -40º to 130º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 580 psi (-1 to 40 bar)
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L w/PTFE inner shield
Process mount: – 40: 4” flange (ANSI), – 60: 6” flange (ANSI)
Classification: Intrinsically safe
Approvals (pending): ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, CRN, RoHS
EchoPro® LR31 Pulse Radar Liquid Level Transmitter
EchoPro® LR31 Pulse Radar Liquid Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA analog and HART digital signal output, and is configured via its remote push button display module or WebCal software. The non-contact liquid level sensor is intended for industrial wastewater, municipal storm or sewer lift station, reservoir, river, canal or open channel applications located below or above grade. Select this sensor for challenging process conditions that may include light surface foam or agitation, small trash or plant material, wind, condensation or vapor. Each comes with a 32.8’ (10m) cable, mounting bracket and display module. The sensor is designed for bracket mount installation suspended above the liquid level.
FEATURES
- Rugged IP68 sensor enclosure with 304 SS mounting bracket
- Configuration via push button display or WebCal PC software
- 26 GHz. pulse radar is unaffected by sump process conditions
- Wall mounted display with windowed enclosure rated IP67
- 12” (30cm) dead band enables utilization of the entire sump
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- HART communication in point to point and multi-drop modes
- Auto-temperature compensation for accurate measurement
- Self diagnostics with selectable fail-safe signal outputs
- Recognition, storage and rejection of false echo signal returns
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
SENSOR
Range: 12” to 98.4’ (30cm to 30m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: 12º
Supply voltage: 21.6 to 26.4 VDC
Max consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 212º, C: -40º to 100º
Temp. comp.: Automatic
Pressure: Atmospheric
Enclosure rating: IP68
Encl. material: Nylon
Cable type: 6-conductor, shielded
Cable length: 32.8’ (10m)
Cable jacket mat.: PVC
Process mount: 304 SS bracket or 1” NPT
DISPLAY
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Enclosure type: Wall mount
Enclosure rating: IP67
Encl. material: Polycarbonate
Conduit entrance: (2) 1/2” NPT connectors
COMMON
Memory: Non-volatile
Storage temp.: F: -40º to 176º, C: -40º to 80º
Classification: Intrinsically safe
Approvals (pending): ATEX IIG Ex ia II C T6…T3 Ga; IEC Exia IIC T6…T3 Ga; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, RoHS
EchoPulse® LR10 Pulse Radar Liquid Level Transmitter
EchoPulse® LR10 Pulse Radar Liquid Level Transmitter
APPLICATION
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy process conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.
FEATURES
- PTFE encapsulated antenna and mount for corrosive media
- Simple configuration via integral push button display module
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- Rugged IP67 aluminum enclosure with polycarbonate window
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 12” to 32.8’ (30cm to 10m)
Frequency: 26 GHz.
Accuracy: ± 5mm
Dead band: 12” (30cm)
Beam angle: 22º
Configuration: Push button
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 266º, C: -40º to 130º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 43.5 psi (-1 to 3 bar)
Enclosure rating: IP67
Encl. material: Aluminum w/silicone gasket, PBT FR neck & wrench flat
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug
Antenna material: PTFE
Process mount: 1 1/2” NPT
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, RoHS
EchoPulse® LR15 Pulse Radar Liquid Level Transmitter
EchoPulse® LR15 Pulse Radar Liquid Level Transmitter
APPLICATION
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for petroleum, water, wastewater and diluted chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with low or non-corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a tank adapter, flange fitting or metal stand-pipe. Typical applications include bulk storage, tanker truck, process tank, waste sump and neutralization tanks.
FEATURES
- Rugged 316L stainless steel antenna and process mount
- Simple configuration via integral push button display module
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- Rugged IP67 aluminum enclosure with polycarbonate window
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 12” to 98.4’ (30cm to 30m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 20: 18º, – 30: 12º, – 40: 8º
Configuration: Push button
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -76º to 302º, C: -60º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 150 psi (-1 to 10 bar)
Enclosure rating: IP67
Encl. material: Aluminum w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug
Antenna material: 316L
Process mount: 1 1/2” NPT
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, CRN, RoHS
EchoPulse® LR20 Pulse Radar Liquid Level Transmitter
EchoPulse® LR20 Pulse Radar Liquid Level Transmitter
APPLICATION
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.
FEATURES
- 316L antenna with PTFE inner shield for corrosive media
- Simple configuration via integral push button display module
- 26 GHz. pulse radar is unaffected by vapor or condensation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- Rugged IP67 aluminum enclosure with polycarbonate window
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 12” to 65.6’ (30cm to 20m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: – 30: 12º, – 40: 8º
Configuration: Push button
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 302º, C: -40º to 150º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 72 psi (-1 to 5 bar)
Enclosure rating: IP67
Encl. material: Aluminum w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug
Antenna material: 316L w/PTFE inner shield
Process mount: – 30: 3” flange (ANSI), – 40: 4” flange (ANSI)
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, CRN, RoHS
EchoPulse® LR25 Pulse Radar Liquid Level Transmitter
EchoPulse® LR25 Pulse Radar Liquid Level Transmitter
APPLICATION
The general purpose 6.3 GHz. pulse radar level transmitter provides continuous level measurement up to 114.8’ (35m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical and petroleum storage or process applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for harsh process conditions with corrosive or low dielectric media, heavy surface foam or agitation, higher pressure, steam, condensation or vapor, and installation in a flange fitting. Due to the wider beam angle, special attention should be given to ensure that the sensor is located with unobstructed measurement space. Typical applications include process tanks.
FEATURES
- 316L antenna with PTFE inner shield for corrosive media
- Simple configuration via integral push button display module
- 6.3 GHz. pulse radar is unaffected by most foam and agitation
- 12” (30cm) dead band enables utilization of the entire tank
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- Rugged IP67 aluminum enclosure with polycarbonate window
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
Range: 12” to 114.8’ (30cm to 35m)
Frequency: 6.3 GHz.
Accuracy: ± 10mm
Dead band: 12” (30cm)
Beam angle: 20º
Configuration: Push button
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 266º, C: -40º to 130º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -14.5 to 580 psi (-1 to 40 bar)
Enclosure rating: IP67
Encl. material: Aluminum w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector, (1) M20 x 1.5 plug
Antenna material: 316L w/PTFE inner shield
Process mount: – 40: 4” flange (ANSI), – 60: 6” flange (ANSI)
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, CRN, RoHS
EchoPulse® LR30 Pulse Radar Liquid Level Transmitter
EchoPulse® LR30 Pulse Radar Liquid Level Transmitter
APPLICATION
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its remote push button display module. The non-contact liquid level sensor is intended for industrial wastewater, municipal storm or sewer lift station, reservoir, river, canal or open channel applications located below or above grade. Select this sensor for challenging process conditions that may include light surface foam or agitation, small trash or plant material, wind, condensation or vapor. Each comes with a 32.8’ (10m) cable, mounting bracket and display module. The sensor is designed for bracket mount installation suspended above the liquid level.
FEATURES
- Rugged IP68 sensor enclosure with 304 mounting bracket
- Simple configuration via remote push button display module
- 26 GHz. pulse radar is unaffected by sump process conditions
- Wall mounted display with windowed enclosure rated IP67
- 12” (30cm) dead band enables utilization of the entire sump
- LCD displays level in feet or meters with percent of span bar
- Optional display mode indicates the echo signal return curve
- Self diagnostics with selectable fail-safe signal outputs
- Recognition, storage and rejection of false echo signal returns
LITERATURE
Data Sheet | Quick Start | Manual | Brochure
SPECIFICATIONS
SENSOR
Range: 12” to 98.4’ (30cm to 30m)
Frequency: 26 GHz.
Accuracy: ± 3mm
Dead band: 12” (30cm)
Beam angle: 12º
Supply voltage: 16-26 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 212º, C: -40º to 100º
Temp. comp.: Automatic
Pressure: Atmospheric
Enclosure rating: IP68
Encl. material: Nylon
Cable type: 6-conductor, shielded
Cable length: 32.8’ (10m)
Cable jacket mat.: PVC
Process mount: 304 bracket or 1” NPT
DISPLAY
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Configuration: Push button
Enclosure type: Wall mount
Enclosure rating: IP67
Encl. material: Polycarbonate
Conduit entrance: (2) 1/2” NPT connectors
COMMON
Memory: Non-volatile
Storage temp.: F: -40º to 176º, C: -40º to 80º
Classification: General purpose
Certification: cTUVus, FCC
Compliance: CE, RoHS
EchoPro® LR36 Pulse Radar Solids Level Transmitter
EchoPro® LR36 Pulse Radar Solids Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 49.2’ (15m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact solids level sensor is intended for dry solid media including aggregates, grains, pellets, powders and building materials. Select this sensor for easy process conditions with minimal dust and installation with an adjustable mounting bracket or gimbal flange. Typical applications include bins, transfer stations and crushers.
FEATURES
- Rugged 316L stainless steel antenna and process mount
- Configuration via push button display or WebCal software
- Gimbal flange for easy positioning with the angle of repose
- LCD displays level in feet or meters with percent of span bar
- HART communication in point to point and multi-drop modes
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 49.2’ (30cm to 15m)
Frequency: 26 GHz.
Accuracy: ± 10mm
Dead band: 12” (30cm)
Beam angle: 8º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 392º, C: -40º to 200º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: -40: -14.5 to 580 psi (-1 to 40 bar), -44 & -45: Atmospheric
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L
Process mount: -40: 1 1/2” NPT, -44: 4” gimbal flange (ANSI), -45: 5” gimbal flange (ANSI)
Classification: Intrinsically safe
Approvals (pending): ATEX II 1C Ex ia III C T76º C…T146º C Da; IEC Ex ia III C T76º C…T146º C Da; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, RoHS
EchoPro® LR41 Pulse Radar Solids Level Transmitter
EchoPro® LR41 Pulse Radar Solids Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 229.7’ (70m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact solids level sensor is intended for dry solid media including aggregates, grains, pellets, powders and building materials. Select this sensor for challenging process conditions with moderate to significant dust, and installation with an adjustable gimbal flange or mounting bracket. Typical applications include silos, stockpiles, transfer stations and crushers.
FEATURES
- Rugged 316L stainless steel antenna and process mount
- Configuration via push button display or WebCal software
- Gimbal flange for easy positioning with the angle of repose
- Antenna air-purge for use with significant dust conditions
- LCD displays level in feet or meters with percent of span bar
- HART communication in point to point and multi-drop modes
- Optional display mode indicates the echo signal return curve
- Fail-safe diagnostics with selectable signal fail-safe outputs
- PTFE antenna cover for use with moderate dust conditions
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 229.7’ (30cm to 70m)
Frequency: 26 GHz.
Accuracy: ± 15mm
Dead band: 12” (30cm)
Beam angle: -5_21-4: 8º, -5_21-5: 6º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 752º, C: -40º to 400º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: Atmospheric
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: -5_21-4/5: 316L, -5_21-A/B: 316L & PTFE
Air purge fitting: 1/4” (6.3mm) I.D. tubing
Process mount: -_0: 1 1/2” NPT, -_4: 4” gimbal flange (ANSI), -_5: 5” gimbal flange (ANSI)
Classification: Intrinsically safe
Approvals (pending): ATEX II 1C Ex ia III C T76º C…T146º C Da; IEC Ex ia III C T76º C…T146º C Da; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, RoHS
EchoPro® LR46 Pulse Radar Solids Level Transmitter
EchoPro® LR46 Pulse Radar Solids Level Transmitter
APPLICATION
The intrinsically safe 26 GHz. pulse radar transmitter provides continuous level measurement up to 229.7’ (70m) with a 4-20 mA analog and HART digital signal output, and is configured via its integral push button display module or WebCal software. The non-contact solids level sensor is intended for dry solid media including aggregates, grains, pellets, powders and building materials. Select this sensor for the most difficult process conditions with significant to extreme dust, and installation with an adjustable gimbal flange. For ease of installation, the parabolic antenna can be unclamped, inserted through the base of a riser, and reattached to the sensor. Typical applications include silos.
FEATURES
- Parabolic antenna delivers high power RF signal strength
- Configuration via push button display or WebCal software
- Gimbal flange for easy positioning with the angle of repose
- LCD displays level in feet or meters with percent of span bar
- HART communication in point to point and multi-drop modes
- Optional display mode indicates the echo signal return curve
- Rugged 316L stainless steel antenna and process mount
- Fail-safe diagnostics with selectable signal fail-safe outputs
- Recognition, storage and rejection of false echo signal returns
- IP67 stainless enclosure with polycarbonate display window
WEBCAL SOFTWARE
WebCal software is a PC utility program that enables users to easily configure and test compatible Flowline level sensors to their measurement and control requirements. Download your free copy.
LITERATURE
SPECIFICATIONS
Range: 12” to 229.7’ (30cm to 70m)
Frequency: 26 GHz.
Accuracy: ± 15mm
Dead band: 12” (30cm)
Beam angle: – 8_: 5º, – 0_: 4º
Configuration: Push button; WebCal® PC Windows®USB® 2.0; HART 7
Memory: Non-volatile
Display type: LCD, dot matrix
Display units: Feet and meters
Display bar: Percent of span
Display graph: Echo signal curve
Supply voltage: 21.6 to 26.4 VDC
Max. consumption: 22.5 mA
Signal output: 4-20 mA, two-wire, HART 7
Signal invert: 4-20 mA, 20-4 mA
Signal fail-safe: 3.9 mA, 20.5 mA, 22 mA
Process temp.: F: -40º to 752º, C: -40º to 400º
Temp. comp.: Automatic
Storage temp.: F: -40º to 176º, C: -40º to 80º
Pressure: Atmospheric
Enclosure rating: IP67
Encl. material: 316L stainless steel w/silicone gasket
Encl. window mat.: Polycarbonate
Conduit entrance: (1) 1/2” NPT connector
Antenna material: 316L & PTFE
Process mount: -_4: 4” gimbal flange (ANSI), -_5: 5” gimbal flange (ANSI)
Classification: Intrinsically safe
Approvals (pending): ATEX II 1C Ex ia III C T76º C…T146º C Da; IEC Ex ia III C T76º C…T146º C Da; CSA Class I, Div 1, Groups A, B, C & D; Class II, Groups E, F & G; Class I Zone 0 IIC & Zone 20 Group IIC
Certification: FCC
Compliance: CE, RoHS